BOKI Industries

Heating systems specialist

Heat output regulators and other accessories

Thermostatic valve DN15 - shortened NF version

PN10/110 °C
Straight version DN15 Corner version DN15

 

Regulating and stop valves DN15

PN10/110 °C
Straight version DN15 Corner version DN15

 

Thermostat with remote adjustment

Setting range - 8-28 °C C
Capillary length - 2 m
Frost protection - 8 °C

 

Room thermostat

Operating voltage - 24-250V / 50 or 60 Hz
Temperature range - 8-30 °C
Amperes - 0,2-6 (2) A
Level of water tightness- IP 30
Colour - white RAL 9010
Dimensions - 96,4 x 99,6 x 42,8 mm

 

Thermostatic valve actuator

Operating voltage - 24V/50 Hz or 230V/50 Hz
Length of cable - 1,2 m
Power consumption - 2.5 W at 58 VA and 230 V / 50 Hz, 2.5 W at 6 VA and 24 V / 50 Hz
Circuit breaker - 250 mA (24 V/50 Hz, 230 V/50 Hz)
Connecting cable- 2 x 0,75 mm2
Level of water tightness - IP 41

NB: Not to be installed at less than horizontal. PTP-01 - open when no current PTP-02 closed when no current

 

Manual three-step speed switch

Operating voltage- 250V/50 nebo 60 Hz
Number of speeds - off + 3
Load capacity- 0,2-6 (2) A
Level of water tightness - IP 30
Colour - white - RAL 9010
Dimensions - 96,4 x 113,1 x 42 mm

 

Room thermostat with three-step speed switchh

Operating voltage - 250V/50 nebo 60 Hz
Temperature range - 8-30 °C
Number of speeds - off + 3
Load capacity- 0,2-6 (2) A
Level of water tightness - IP 30
Colour -white - RAL 9010
Dimensions- 96,4 x 113,1 x 42 mm

NB: The thermostat should be placed about 1.5 m above the floor to avoid being affected by the sun or other souces of heat or cold.

 

Temperature sensor for thermostats PER-03, 04

Operating range - 0-40 °C
Measuring sensor NTC, 3 kΩ at 25 °C
Accuracy at 25 °C - ±0.3 K
Time segments (for air circulation) - cca. 6 min
Connection terminals - 2 x 1.5 mm2 or 1 x 2.5 mm2

 

Remote controls for PER-03-IR, PER-04-IR, PER-05-IR a PER-06

 

Room thermostat with automatic rotation direction switch PER-05 (RDF300.02)
PER-06 (RDF400.01) – with a weekly programme and sensors for infra-red

red remote control
For 2 and 4 pipe applications
Backlit LCD display
Operating voltage - 230V / 50 Hz
Consumption - max. 8VA
Control outputs - load capacity- 230V//50 Hz, max. 4 (2)A
Level of water tightness- IP 30
Temperature range - 5-40 °C
Impellor speed control - manual (0,1,2,3)/automatic
Dimensions - 86 x 86 x 14 mm
Concealed mounting in rectangular boxes - supplied

 

Room thermostat with automatic rotation direction switch PER-07
(RDG100) and weekly programme PER-08 (RDG100T)

Operating voltage - 230V / 50 Hz
Consumption - max. 8VA
Control outputs - load capacity- 230V//50 Hz, max. 4 (2)A
Level of water tightness- IP 30
Temperature range - 5-40 °C
Impellor speed control - manual (0,1,2,3)/automatic
Dimensions - 93 x 128 x 31 mm

 

230 / 12V 3-stage speed trench convector controller

NB: The listed price of the speed controller RAU is extra to the gross price of the convector - see convector order code.

 

PAT speed controller - on wall

The wall-mounted PATspeed controller works only with a mechanical thermostat, must not be wired in parellel.

 

PAT speed controller - in wall

The wall-mounted PATspeed controller works only with a mechanical thermostat, must not be wired in parellel.

 

PAT speed controller - on wall

The wall-mounted PATspeed controller works with a free choice of thermostat, must not be wired in parellel.

 

PAT speed controller - in wall

The wall-mounted PATspeed controller works only with a free choice of thermostat, must not be wired in parellel.

 

PAT speed controller (transformer, IP 68)

This speed controller is for installation directly in convector trenchs with a height of min. 90 mm. Direct control only by mechanical thermostat PPT-02; for other thermostats it is necessary to use control module PAT.

 

Modules for operating the PAT speed controller

Module for operating 1 x PAT speed controller PAT-xx-T-04 for on-wall installation
Module for operating 2 x PAT speed controllers PAT-xx-T-04 for on-wall installation
Module for operating 3 x PAT speed controllers PAT-xx-T-04 for on-wall installation
Module for operating 4 x PAT speed controllers PAT-xx-T-04 for on-wall installation
Module for operating 5 x PAT speed controllers PAT-xx-T-04 for on-wall installation
Module for operating 6 x PAT speed controllers PAT-xx-T-04 for on-wall installation
Module for operating 1 x PAT speed controller PAT-xx-T-04 for in-wall installation
Module for operating 2 x PAT speed controllers PAT-xx-T-04 for in-wall installation
Module for operating 1 x PAT speed controller PAT-xx-T-04 for in-convector trench installation
Module for operating 2 x PAT speed controllers PAT-xx-T-04 for on-wall installation

 

Impellor limiting set

Impellor limiting set - unless the water temperature is above 35 ° C, installed directly on the heat convector

 

Set for installation in raised floors

Settings range from 20-200 mm. Recommended amount: Total length of convector / 500 mm + 1 pc. Specific dimensions to be determined after consultation with the manufacturer. Example order code: FZH-26-210

Did not find what you were looking for? Send us a question.

Items marked * are required

Your name Your e-mail * Your phone
Your message *
Please fill in the result (number) nine plus six:

Do you have a question?+420 545 216 104

Division Heating is based in BrnoShow on map

BOKI Industries a.s.
Palackého třída 1643/10
613 00 Brno
Česká republika

Phone: +420 545 216 104
E-mail: heat@bokigroup.eu

© 2020 BOKI Industries a.s.